Hewlett Packard Enterprise (HPE) in Roseville, California, faced increasing electromagnetic interference (EMI) challenges as its Ethernet switch products grew in complexity and regulatory requirements tightened. Long EMC test and intermittent-troubleshooting times threatened chamber capacity and throughput, so HPE engaged Keysight to improve measurement speed and capture reliability, deploying the Keysight N9048B PXE EMI receiver together with TOYO EPX / RE software.
Keysight’s solution used the PXE N9048B’s accelerated time-domain scan (A‑TDS) and real-time scan (RTSC) gapless capture with up to 350 MHz FFT bandwidth, enabling simultaneous frequency- and time-domain analysis. With Keysight’s system HPE achieved roughly 10× faster measurements, continuous monitoring of noise amplitudes, and a reduction in EMI troubleshooting from more than two hours to about 10 minutes (up to ~90% fewer person-hours), significantly improving lab throughput and debug efficiency.
David Bernal
Laboratory Manager